Flame Sensor Bad Ground

Flame Sensor Bad Ground. Second, if you can actual see soot covering the tip of the sensor, it’s time for a cleaning. If you connect a diode, like a 1n4004 in series with a 1 meg resistor to your board in place of the flame sensor, you should be able to measure at least a few microamps.

LB White® 3" Flame Sensor for 60M/100M HSI Hog Slat
LB White® 3" Flame Sensor for 60M/100M HSI Hog Slat from www.hogslat.com

We found that the hanger on the exhaust pipe was hung poorly and causing exhaust pipe to droop down which made it hold condensation that ran back into unit which shut the furnace down. A number of signs that your flame sensor is fouled, corroded or otherwise bad are easily detected. Second, if you can actual see soot covering the tip of the sensor, it’s time for a cleaning.

Since Your Furnace Is Still Having What Sounds Like Flame Sensing Problems I Would Suggest Making Sure The Flame Sensor Is Positioned In The Flame Where It Is Getting A Good Hot Blue Flame To Sense.


Bad ground to the board. Rust and corrosion are other very common problems for flame sensors and they too are caused by infrequent cleaning and maintenance. How many seconds between burners igniting and extinguishing?

The Root Of The Problem Often Lies At The Flame Sensor Of The Furnace.


Sounds like the board isn't recognizing the flame rectification through the flame sensor, judging by your readings. This is a video of a real flame sensor that is bad. Signs your flame sensor is bad.

I Know When A Flame Sensor Is Going Bad Or Dirty The Micro Amps (Ua) Go Down (I.e., 3.1,2.9,1.1, And On).


The presence of flame completes that circuit. If there isn't it could be a faulty board. It could be anything ie bad ground, flame sensor, weak output, gas pressure, gas quality and there really is no way to know without troubleshooting it to see what the problem is.

That’s Why This Sensor Module Is Used In Flame Alarms.


After cleaning the flame sensor, checking ground wire, checking exhaust for cracks or blockage and the board connection which did not fix it. The anode of the diode usually goes to the flame rod connection,. A bad flame sensor can result in all kinds of frustrations.

I Used My Meter To Measure Micro Amps On A Customers Furnace Flame Sensor Which Measured 5.1 Ua.


How the flame sensor works is by a small ac electrical charge going through the sensor and it uses the flame to carry the electrical power to ground. A bad flame sensor won’t feel the heat and shut the furnace down when the unit has fired, and it’s already burning hot. This is a great video that shows how the fu.